Product Details:

  • Tensile Strength High
  • Life Span Up to 12 Months (depending on use)
  • Purity >99.99% Platinum
  • Strength High Chemical and Mechanical Stability
  • Copper Thickness N/A (Platinum used)
  • Diameter 1.6 mm active area
  • Product Type Screen Printed Electrode
  • Click to View more
X

Platinum Screen Printed Electrode Price And Quantity

  • 450 INR/Piece
  • 10 Piece
  • 3 mm diameter (working electrode)
  • Platinum
  • Alumina/Ceramic
  • Store in dry, dust-free environment
  • Vacuum-sealed, 50 pcs per pack
  • Single-use (recommended)
  • ~500 nm
  • -20°C to 80°C
  • Silver/Silver Chloride (Ag/AgCl) integrated
  • Three Electrode System: Working, Reference, Counter
  • Standard PCB Edge Connector
  • Yes

Platinum Screen Printed Electrode Product Specifications

  • White base with Platinum track
  • 1.6 mm active area
  • Screen Printed Platinum Layer
  • N/A (Platinum used)
  • Rectangular
  • 0.05 mm
  • Screen Printed Electrode
  • 34 mm x 10 mm x 0.5 mm
  • High Chemical and Mechanical Stability
  • Platinum, Ceramic Substrate
  • Electrochemical Sensing
  • Biosensors, Electrochemical Analysis, Point-of-Care Devices
  • High
  • >99.99% Platinum
  • Up to 12 Months (depending on use)
  • Approx. 0.5 g
  • 3 mm diameter (working electrode)
  • Platinum
  • Alumina/Ceramic
  • Store in dry, dust-free environment
  • Vacuum-sealed, 50 pcs per pack
  • Single-use (recommended)
  • ~500 nm
  • -20°C to 80°C
  • Silver/Silver Chloride (Ag/AgCl) integrated
  • Three Electrode System: Working, Reference, Counter
  • Standard PCB Edge Connector
  • Yes

Product Description

Product Name

Screen Printed Electrodes (Carbon, Silver, Platinum & Gold etc.)

Product Code

NCZ-SPE-101

Diameter of WE

2 mm, 3 mm, 4 mm, 5 mm

Size of RE

0.5 x 1 mm

Ratio CE/WE Surface Area

4/1

Shape

Rectangle

Overall Dimension

50 x 10 mm

Thickness

0.5 mm

Thickness of Coated Material

10 m

Working Electrode

Graphite/Gold/Graphene/CNT/Platinum/Silver (customization possible)

Counter Electrode

Graphite/Gold/Silver/Platinum

Reference Electrode

Ag/AgCl

Substrate

Valox FR1

Packaging

10, 40, 50, 100, 200, 500, 1000 Pcs etc.

 

Please contact for customization.

If the item shown is not exactly whatyou require, please let us know by sending us a message

 

 



Superior Electrochemical Sensing Performance

With a three-electrode setup comprising platinum (working), Ag/AgCl (reference), and a counter electrode, this screen-printed sensor is engineered for robust performance in applications such as biosensors and point-of-care diagnostics. Its platinum layer ensures reliable signal transduction and high durability across demanding analytical scenarios.


Durable, Safe, and User-Friendly Design

Manufactured on an alumina/ceramic substrate with a precisely deposited 500 nm platinum layer, these electrodes boast outstanding chemical and mechanical stability. The RoHS-compliant, single-use format combined with vacuum-sealed packaging guarantees safety, ease of use, and contamination prevention during storage and transportation.

FAQ's of Platinum Screen Printed Electrode:


Q: How should the Platinum Screen Printed Electrode be stored to maintain its quality?

A: The electrode should be stored in a dry, dust-free environment and kept in its original vacuum-sealed packaging until use. Proper storage conditions help preserve the electrode's chemical integrity and prevent contamination.

Q: What is the recommended usage process for these electrodes in electrochemical analysis?

A: To use the electrode, connect it via the standard PCB edge connector to your analytical instrument. Apply your test solution to the working area (3 mm diameter), and proceed with your electrochemical measurement, ensuring single-use for optimal data accuracy.

Q: When is it advisable to dispose of the electrode after use?

A: It is recommended to dispose of the Platinum Screen Printed Electrode after a single use, as reuse may compromise analytical accuracy and introduce contamination from previous samples.

Q: Where are these electrodes commonly applied?

A: These electrodes are widely used in biosensor development, point-of-care medical devices, and various electrochemical analyses in research labs, hospitals, and diagnostic centers.

Q: What are the benefits of using platinum and ceramic materials in this electrode?

A: Platinum's high purity and conductivity enable sensitive detection, while the ceramic substrate offers high chemical and mechanical stability. This ensures reliable results and durable performance under a range of laboratory conditions.

Q: How long can the electrode be stored before use?

A: Each electrode maintains optimal performance for up to 12 months when stored correctly. Always check packaging integrity and avoid exposure to moisture or dust.

Q: What makes this electrode suitable for Canadian exporters, dealers, and researchers?

A: Its compliance with RoHS regulations, convenience in bulk (50 pcs/pack), and compatibility with global instrumentation standards make it a versatile and reliable choice for dealers, exporters, researchers, and professionals across Canada.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Electrode' category



Back to top