Formvar on 3mm H7 Finder Au Grids (Pack of 25)

Formvar on 3mm H7 Finder Au Grids (Pack of 25)

Product Details:

  • Melting Point Around 120C to 140C (Formvar resin)
  • Storage Store at room temperature, protected from moisture and dust
  • Purity 99.9% (Gold grid)
  • Form Thin film on grid
  • Smell Odorless
  • Boiling point Not applicable (polymer)
  • Solubility Insoluble in water, soluble in organic solvents such as chloroform and toluene
  • Click to View more
X

Formvar on 3mm H7 Finder Au Grids (Pack of 25) Product Specifications

  • Polyvinyl formal support film on Au grid
  • 9002-89-5 (Formvar)
  • Circular grid
  • High purity scientific grade
  • Supporting specimens for microscopic imaging and analysis
  • [-CH2-CH(OCH3)-]_n
  • 70179000
  • Variable (polymer; gold grid = 196.97 g/mol atom)
  • 1.20 Gram per cubic centimeter(g/cm3)
  • Formvar (polyvinyl formal) on Gold (Au) grid
  • Yes
  • (C2H3CHO)n (Formvar) + Au
  • Odorless
  • Polymeric film
  • Around 120C to 140C (Formvar resin)
  • Store at room temperature, protected from moisture and dust
  • Thin film on grid
  • Transmission Electron Microscopy (TEM) specimen support film
  • 99.9% (Gold grid)
  • EM grid quality
  • Insoluble in water, soluble in organic solvents such as chloroform and toluene
  • Neutral
  • Polyvinyl formal (Formvar) on Gold Grid
  • Not applicable (polymer)
  • 3mm H7 Finder Au Grid with Formvar film
  • Compatible with most TEM holders and specimen mounting
  • Gold-colored finder grid with translucent Formvar film
  • Pack of 25 grids
  • Electron microscopy laboratories and research institutions
  • Approximately 25 m (gold grid)
  • One side Formvar-coated
  • Typically 10-30 nm (Formvar film)
  • Handle with fine forceps to avoid damage
  • 3 mm diameter
  • H7 finder pattern for specimen localization
  • Finder grid (no mesh count)
  • At least 2 years under appropriate conditions

Formvar on 3mm H7 Finder Au Grids (Pack of 25) Trade Information

  • Cheque, Telegraphic Transfer (T/T), Paypal, Cash in Advance (CID)
  • All India

Product Description

Formvar  coated grids without a carbon layer are suitable for TEM applications up to 100kV. The films are available on grids made of copper, nickel or gold.

Supplied as 25 grids in a grid box.

Gold

Formvar support films can be applied to other grid sizes, material or type. Further details available on request.



High-Precision H7 Finder Design

The H7 finder pattern allows researchers to efficiently locate and relocate specific specimen regions under the electron microscope. This significantly enhances workflow efficiency, making targeted imaging and repeated analysis straightforward.


Robust and Transparent Formvar Support

The one-sided Formvar coating, with a film thickness averaging between 10-30 nm, offers an optimal balance of mechanical strength and electron transparency. This provides dependable support for delicate specimens while maintaining imaging clarity.


Engineered for TEM Compatibility

With a standard 3 mm circular diameter and sturdy gold grid construction, these grids integrate seamlessly with the majority of specimen holders utilized in transmission electron microscopes. The gold material ensures 99.9% purity for reliable scientific analysis.

FAQs of Formvar on 3mm H7 Finder Au Grids (Pack of 25):


Q: How should the Formvar on 3mm H7 Finder Au Grids be handled to prevent damage?

A: Handle these grids only with fine forceps and avoid direct contact with the Formvar film to prevent tears or contamination. Always work in a clean, dust-free environment for optimal preservation.

Q: What are the main benefits of using the H7 finder pattern gold grids in TEM analysis?

A: The H7 finder pattern enables researchers to easily localize and revisit specific specimen areas, improving accuracy and efficiency in imaging sessions. The gold grid also provides high purity and chemical stability.

Q: When are these grids typically used during specimen preparation?

A: These grids are ideal for supporting samples during the mounting and analysis phases of transmission electron microscopy, especially when precise localization or repeated imaging of specific regions is required.

Q: Where should the Formvar-coated finder grids be stored for best shelf life?

A: Store grids at room temperature, protected from moisture and dust, in their original packaging. Under such conditions, they remain usable for at least 2 years.

Q: What is the process for mounting a specimen onto the Formvar-coated finder grid?

A: Place the specimen onto the Formvar side of the grid using fine forceps or a micromanipulator. If embedding or staining is necessary, ensure all solvents used are compatible with Formvar to prevent film dissolution.

Q: How are these grids compatible with typical TEM holders?

A: The 3 mm circular size and standard thickness ensure compatibility with most TEM specimen holders and mounting stages, allowing quick integration into existing workflows.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Speciality Chemicals & Materials' category



Back to top