Product Details:

  • Density 1.2 Gram per cubic centimeter(g/cm3)
  • Purity High-purity Formvar and copper
  • Form Mesh grid coated with Formvar film
  • Molecular Formula (C3H4O)x for polymer; Cu for grid
  • Structural Formula [-CH2-CH(OCH3)-CH2O-]n for Formvar, Cu lattice
  • Poisonous Yes
  • Storage Store at room temperature, dry environment
  • Click to View more
X

Formvar on 3mm 75 Mesh Cu Grids (Pack of 25) Product Specifications

  • Copper (Cu) grid with Formvar polymer coating
  • Polyvinyl formal (Formvar), Copper grid
  • 810 copper mesh / 3916 polymer film
  • Approximately 170C
  • Disc (grid), thin film coated
  • Analytical/Research grade
  • Used as a specimen support in TEM sample preparation
  • Polymer film on metal grid
  • Variable (polymer), 63.55 for copper
  • Support film for electron microscopy, particularly transmission electron microscopy (TEM)
  • Meets electron microscopy lab standards
  • N/A (Formvar is a trade name)
  • Insoluble in water; soluble in organic solvents such as chloroform and ethylene dichloride
  • 3mm diameter, 75 mesh copper grid coated with Formvar
  • Store at room temperature, dry environment
  • Odorless
  • Polyvinyl formal on copper grid
  • [-CH2-CH(OCH3)-CH2O-]n for Formvar, Cu lattice
  • (C3H4O)x for polymer; Cu for grid
  • Yes
  • Mesh grid coated with Formvar film
  • High-purity Formvar and copper
  • 63148-65-2 (Formvar polymer)
  • 1.2 Gram per cubic centimeter(g/cm3)

Formvar on 3mm 75 Mesh Cu Grids (Pack of 25) Trade Information

  • Paypal, Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque
  • All India

Product Description

Formvar coated grids without a carbon layer are suitable for TEM applications up to 100kV. The films are available on copper grids. Nickel and gold grids are also available.

Supplied as 25 grids in a grid box.



Superior Support for TEM Applications

These grids offer a stable platform for specimen mounting in transmission electron microscopy. The Formvar-coated copper ensures minimal artifact introduction, delivering clear imaging results and high electron transparency. Widely utilized in research and analytical laboratories for biological and material sciences, these grids facilitate detailed examination of ultrastructural features.


Uniform Coating and Excellent Compatibility

The grids are manufactured with a uniform Formvar coating between 10-30 nm, providing a smooth, defect-free film. They are highly compatible with most TEM sample preparation protocols, minimizing sample disruption and supporting a variety of specimen types, including delicate biological samples and fine material particles.


Reliable Storage and Longevity

Supplied in packs of 25, these grids maintain integrity when stored in a dry environment at room temperature. With a shelf life of two years under recommended conditions, researchers can depend on consistent grid quality throughout their experiments.

FAQs of Formvar on 3mm 75 Mesh Cu Grids (Pack of 25):


Q: How should I store the Formvar on 3mm 75 Mesh Cu grids to maintain their quality?

A: Store the grids in a dry environment at room temperature, protected from moisture and dust. This preserves the smooth, defect-free Formvar film and maintains grid performance for up to 2 years.

Q: What are the main benefits of using Formvar-coated copper grids for TEM?

A: Formvar-coated copper grids provide high electron transparency, a stable support film, and a smooth surface that minimizes imaging artifacts. They boost the quality and reliability of specimen imaging in TEM applications.

Q: Where can I use these 3mm 75 Mesh Cu grids?

A: These grids are widely used in biological and materials science laboratories for TEM specimen preparation. They are suitable for research and analytical applications requiring artifact-free, high-resolution electron microscopy.

Q: What is the recommended process for preparing specimens on Formvar-coated grids?

A: Specimens are typically placed directly onto the Formvar-coated surface. The smooth film helps create an even support for samples, and the grid is then mounted in the TEM sample holder for imaging.

Q: When should I replace unused grids from my pack?

A: Replace grids if the Formvar film appears damaged, or after their shelf life of 2 years has elapsed. Proper storage helps maximize their usable period.

Q: What solvents are suitable for dissolution or removal of Formvar from the grid?

A: Formvar is insoluble in water but is soluble in organic solvents such as chloroform and ethylene dichloride. These may be used in laboratory processes requiring film removal.

Q: What is the benefit of the 75 mesh size and 3 mm diameter specification?

A: The 75 mesh size provides an optimal balance between support and open space for sample observation, while the 3 mm diameter fits standard TEM sample holders, ensuring compatibility and ease of use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Speciality Chemicals & Materials' category



Back to top